  • What is the nature of the problem? Related to heating. Issue with Pump(s).
  • check motor module.
  • what's wrong with heating zones? Actual temperatures not correct. Actual temps o.k. but one zone not heating. Actual temp o.k. but no zone is heating. One or several zones are overheating.
  • check RTD/RTD connection.
  • check main contactor.
  • check power modules.
  • What is wrong with actual temperatures? One or several actual temperatures show '?". All actual temperatures show "?". Actual temperatures are shown but wrong values.
  • Check RTD/RTD connections.
  • Is the ASU properly configured? yes, zone table is o.k.. No, zone table is empty or incorrect.
  • Re-configure the V6-system.
  • Is the V6-System running properly? Check modules green lights. yes, all modules show green lights. No, not all modules show green lights.
  • V6-Temp module defective.
  • Check V6 modules and connections.
  • Is the RTD selector set properly? Yes. No.
  • 1. RTD's are incorrect / defective . 2. V6-TEMP Module is defective.
  • Change the Jumper Position.